Application of the Minor Destructive Test (MDT) method for determination of AAC masonry compressive strength

Main Article Content

Radosław Jasiński
Łukasz Drobiec
Wojciech Mazur

Abstract

Non-destructive methods (NDT) in masonry made of autoclaved aerated concrete (AAC) are not used as commonly as in concrete or reinforced concrete constructions. The porous structure and sensitivity to atmospheric factors, especially humidity, makes it necessary to determine the compressive strength of the wall in existing and used objects. The article presents a proposal of a semi-non-destructive method for determining the compressive strength of AAC, and then a wall made with thin-layer joints. An empirical curve developed for cellularconcrete with nominal density classes 400, 500, 600 and 700 in an air-dry condition was used for calibration.In addition, an empirical relationship was developed to take into account the impact of ABK moisture.

Downloads

Download data is not yet available.

Article Details

How to Cite
[1]
R. Jasiński, Łukasz Drobiec, and W. Mazur, “Application of the Minor Destructive Test (MDT) method for determination of AAC masonry compressive strength”, Weld. Tech. Rev., vol. 91, no. 2, Feb. 2019.
Section
Original Articles

References

B. A. Suprenant, M. P. Schuller, Nondestructive Evaluation & Testing of Masonry Structures, Hanley Wood Inc, ISBN 978-0924659577.

R. Orłowicz, P. Tkacz, P. Bilko: Metody badań wytrzymałości muru w budynkach istniejących. XXVI Ogólnopolskie Warsztaty Pracy Projektanta Konstrukcji. Bielsko-BiałaSzczyrk, 9-12.03.(2011), tom II, 163-182.

P. Matysek, Metody określania wytrzymałości murów w konstrukcjach istniejących, XXX Jubileuszowe Ogólnopolskie Warsztaty Pracy Projektanta Konstrukcji. Bielsko-BiałaSzczyrk, 25-28.03.(2015), tom II, 435-462.

PN-EN 771-4:2011 Wymagania dotyczące elementów murowych. Część 4. Elementy murowe z autoklawizowanego betonu komórkowego.

A.M. Neville: Włściwości betonu. 5th edition, Pearson Education Limited (2011), Essex, England.

Ł. Drobiec, R. Jasiński, A. Piekarczyk, Konstrukcje Murowe według Eurokodu 6 i norm związanych. Tom 1, Wydawnictwo Naukowe PWN (2013), Warszawa.

K. Łaskawiec, L. Misiewicz, Deklarowane i uzyskiwane z badań właściwości użytkowe elementów murowych z ABK produkowanych w Polsce,Materiały Budowlane (2014), 11, 46-47.

G. Zapotoczna-Sytek, S. Balkovic, Autklawizowany beton komórkowy. Technologia. Właściwości. Wykonawstwo, Wydawnictwo Naukowe PWN (2013), Warszawa.

W. Mazur, Ł. Drobiec, R. Jasiński, Effects of specimen dimensions and shape on compressive strength of specific autoclaved aerated concrete. ICAAC 6th International Conference on Autoclaved Aerated Concrete,Postdam 4-6 september (2018), 541-556, DOI.ORG/10.1002/ cepa.837.

R. Jasiński, Ł. Drobiec, W. Mazur, Validation of selected non-destructive methods for determining the compressive strength of masonry units made of autoclaved aerated concrete, Materials (2019), vol. 12 (3), art. no. 389, 1-21.

R. Jasiński, Wyznaczanie wytrzymałości na ściskanie muru z autoklawizowanego betonu komórkowego metodą małoniszczącą, Badania nieniszczące i diagnostyka (2018), 3, 81-85, DOI: 10.26357/BNiD.2018.029.

W. Weibull, A Statistical Theory of Strenght of Materials, Ingvetenskaps Handl (1939).

W. Weibull, A statistical distribution function of wide applicability, Journal of Applied Mechanics (1951), vol.18, 293-297.